OLK51AXPSMST Set
OM120A/OS430ST/AD110/MSP200XP |
|
 |
|
This test set is the complete solution necessary
for the installer to test, terminate, trouble
shoot and document fiber optic systems. The test
set is designed to allow testing of all
parameters of fiber optic networks, including
output power levels from the fiber, coupled
source power and attenuation loss in a fiber.
The test set includes the following
products:
OM120A
The
meter is a general-purpose power meter suitable for a both
premise and outside plant applications. The meter is suitable
for both single-mode and multimode applications, depending on
the source which is used.The
meter measures optical power, loss (attenuation) and optical
return loss. The meter is calibrated at industry standard
wavelengths (NIST traceable). The zero reference function is
ideal for testing fiber optic cables in dB, the reference value
is saved in the power meter. The Sensor size
is 1mm. A universal 2,5 mm universal
adapter with a threaded housing is included, other adapters are
also available as an accessory. Due to the backlight the data is
always visible. The meter is delivered in a
protective rubber boot.
OS430ST
The sender is for outside plant and single-mode fiber. The
connector output can be adapted to any cable plant with hybrid
adapters or hybrid cables. This unit is easy to operate with a
wavelength/power switch, which selects optical wavelengths or
disables the unit. There is also a switch which select between
either the CW or 2 kHz output for the transmitting wavelength. The
light source is designed for performing insertion loss
measurements on fiber optic links when used with an optical
power meter. Whether testing outside plant or premise an optical
source is the perfect tool when combinated with an optical power
meter. The output is stabilized to ensure accurate test results
per current TIA/EIA requirements. The wavelengths are
individually adjustable with a mechanical screw to have a
variable attenuator or to reduce the output power. This make it
able to save battery power when high optical output power is not
necessary, or to turn up the power to test long runs. The sender
is delivered in a protective rubber boot.
MSP200XP
The
MSP200XP is
a high-resolution glass optics scope with 200x magnification for
both multimode and single-mode fibers. The MSP200XP is portable
and is an ideal field tool for inspecting fiber terminations.
The Fiber Microscope utilizes a white LED for coaxial
illumination. Light is focused into the optical path (axis) so
that it comes out the tip of the ferrule and strikes the sample
perpendicular to the fiber end-face. It produces excellent
detail of scratches and contamination. The MSP200XP is equipped
with an attenuating, laser safety filter to reduce the risk of
eye damage when the user accidentally views a fiber with active
emissions. The MSP200XP is equipped with a standard 2,5 mm
adapter, optional is an 1,25 mm adapter.
AD110
This adapter is for mounting the optical fiber connector to the
meter. Due to the screw thread the adapter is easily to connect.
Different adapters are available for different sorts connectors. |
|
Features |
|
OLK51AXPSMST Package Contents: |
1 |
OM120A |
1 |
OS430 |
1 |
MSP200XP |
1 |
AD110 (ST) |
2 |
Product Manual |
1 |
CALM Calibration Meter |
1 |
CALS Calibration
Sender |
1 |
Trim Tool
|
4 |
Alco Wipe |
|
OLK51AXPSMST Options: |
|
- See
options list |
|
|
Specifications |
|
OM120A (GP APPLICATIONS) |
SPECIFICATIONS, KEY FEATURES AND APPLICATIONS |
Applications |
Multimode, Single-mode, Outside Plant and Premise |
Calibrated Wavelength (λ) |
850nm,1300nm, 1310nm, 1490nm & 1550nm |
Dynamic Range |
+3 dBm to -55 dBm |
Detector diameter |
1 mm |
Detector Type |
Germanium (Ge) |
Connectors |
ST, SC, FC |
Adaptor Options |
See
options
lis |
Accuracy (@25°C, -20.0 dBm) |
±0.25 dB |
Measurement Units |
dBm (absolute) - dB (relative) |
Resolution |
0.1 dB |
Controls |
5 Soft Buttons |
Buttons |
On/Off, Backlight,
λ,
dB-dBm, Zero Reference |
Power |
2 AA Batteries
or
AC Power Converter |
Low Battery Indicator |
Yes |
Display |
Graphical LCD with Backlight |
Auto-Shutdown |
Yes |
Protective rubber boot |
Yes |
Testing reference guide |
Yes |
Enclosure Size |
L: 125 mm W: 70 mm H: 30mm |
Weight |
230 gram |
Operation Temperature |
-10°C to +50°C
(45% Hum, non condensing) |
Storage Temperature |
-20°C to +60°C
(75% Hum, non condensing) |
|
OS430ST (Single mode APPLICATIONS) |
SPECIFICATIONS, KEY FEATURES AND APPLICATIONS |
Applications |
Outside plant single-mode |
Wavelength (λ) |
1310nm/1550nm |
Output type |
Laser |
Modulated
Frequencies |
2 kHz/CW (Continuous Wave) |
Stability, 1 hour |
Less than 0.05 dB |
Power Output |
>-8 dBm,
individually adjustable with mechanical screw |
Connector |
ST |
Controls |
Front panelslide switches |
Power |
2 x AA Batteries
or AC Power Converter |
Low battery indicator |
Yes |
Protective rubber boot |
Yes |
Enclosure Size |
L: 125 mm, W: 70 mm, H: 30 mm |
Weight |
180 Grams |
Operation Temperature |
-10°C to +50°C (45% Hum, non condensing) |
Storage Temperature |
-20°C to +60°C (75% Hum, non condensing) |
|
|
MSP200XP |
SPECIFICATIONS, KEY FEATURES AND APPLICATIONS |
Applications |
Multimode and Single mode |
Optical Magnification |
200x |
LED: |
Rated life 100,000 Hrs |
Controls |
Momentary On/Off switch, Fine-Focus control |
Safety Filter |
Built in IR filter |
Adapter
Interface |
2,5 mm universal standard – optional
1,25 mm available |
Power Requirements |
3 pieces 1,5 Volt AAA alkaline Batteries |
Size |
L: 225 mm, Diameter 32 mm |
Weight |
0.6Kg |
Qualified |
CE, RoHS and WEEE |
|
|