Manual   Demo  
OLK62AXPDST Cert. Set OM220A/OS420ST/OS430ST/MSP200XP
 
 
This certification test set is the complete solution necessary for the installer to certify, test, terminate, trouble shoot and document fiber optic systems. The test set is designed to allow testing of all parameters of fiber optic networks, including output power levels from the fiber, coupled source power and attenuation loss in a fiber. The test set includes the following products:

OM220A
The meter is a general-purpose power meter suitable for a both premise and outside plant applications. The meter is suitable for both single-mode and multimode applications, depending on the source which is used.The meter has an user selectable choice of 0,1 or 0,01 dB resolution, on board memory for 500 readings with date and time stamp, a serial port and an USB port for communication with a PC. In the internal memory of the meter 500 readings and results can be stored. The included PC software easily download and document the measurement results stored in the memory. The results can be printed directly in detail or as list from the software or can be saved in a spreadsheet file. The meter measures optical power, loss (attenuation) and optical return loss. The meter is calibrated at industry standard wavelengths (NIST traceable). The zero reference function is ideal for testing fiber optic cables in dB, the reference value is saved in the power meter. A universal 2,5 mm universal adapter with a threaded housing is included, other adapters are also available as an accessory. Due to the backlight the data is always visible. The meter is delivered in a protective rubber boot.

OS420ST
The sender is for premises and campus cabling networks with multimode fiber or for single-mode fibers up to 5 km at 1300 nm. The connector output can be adapted to any cable plant with hybrid adapters or hybrid cables. This unit is easy to operate with only a wavelength/power switch, which selects optical wavelengths or disables the unit. The light source is designed for performing insertion loss measurements on fiber optic links when used with an optical power meter. Whether testing outside plant or premise an optical source is the perfect tool when combined with an optical power meter. The output is stabilized to ensure accurate test results per current TIA/EIA requirements. The wavelengths are individually adjustable with a mechanical screw to have a variable attenuator or to reduce the output power. This make it able to save battery power when high optical output power is not necessary, or to turn up the power to test long runs. The sender is delivered in a protective rubber boot.

OS430ST
The sender is for outside plant and single-mode fiber. The connector output can be adapted to any cable plant with hybrid adapters or hybrid cables. This unit is easy to operate with a wavelength/power switch, which selects optical wavelengths or disables the unit. There is also a switch which select between either the CW or 2 kHz output for the transmitting wavelength. The light source is designed for performing insertion loss measurements on fiber optic links when used with an optical power meter. Whether testing outside plant or premise an optical source is the perfect tool when combined with an optical power meter. The output is stabilized to ensure accurate test results per current TIA/EIA requirements. The wavelengths are individually adjustable with a mechanical screw to have a variable attenuator or to reduce the output power. This make it able to save battery power when high optical output power is not necessary, or to turn up the power to test long runs. The sender is delivered in a protective rubber boot.

MSP200XP
The MSP200XP is a high-resolution glass optics scope with 200x magnification for both multimode and single-mode fibers. The MSP200XP is portable and is an ideal field tool for inspecting fiber terminations. The Fiber Microscope utilizes a white LED for coaxial illumination. Light is focused into the optical path (axis) so that it comes out the tip of the ferrule and strikes the sample perpendicular to the fiber end-face. It produces excellent detail of scratches and contamination. The MSP200XP is equipped with an attenuating, laser safety filter to reduce the risk of eye damage when the user accidentally views a fiber with active emissions. The MSP200XP is equipped with a standard 2,5 mm adapter, optional is an 1,25 mm adapter.

 
Features
 
OLK62AXPDST Package Contents:
1 OM220A
1 OS420ST
1 OS430ST
1 MSP200XP
1 AD110 (ST)
1 SmartWare V3.00
1 CBL100 (OM-2xx to Serial Cable)
1 CBL200 (Serial to USB Cable)
3 Product Manual
1 CALM Calibration Meter
1 CALS Calibration Sender
1 Trim Tool
4 Alco Wipe
 
OLK62AXPDST Options:
   - See options list
 
Specifications
 
OM220A (GP APPLICATIONS) SPECIFICATIONS, KEY FEATURES AND APPLICATIONS
Applications Multimode, Single-mode, Outside Plant and Premise
Calibrated (λ)Wavelength 850nm, 1300nm, 1310nm, 1490nm & 1550nm
Dynamic Range +3 dBm to -55 dBm
Detector Type 2mm Germanium in Modular Housing

Connectors                

ST, SC, FC

Adaptor Options                    

See options list
Accuracy (@25°C, -20.0 dBm) ±0.25 dB
Measurement Units dBm/mW (absolute) - dB (relative)
Resolution 0.1 dB or 0.01 User Selectable
Storage 500 Readings with Time and Date Stamp
Serial Interface Yes
USB Interface Yes
PC Software Documentation Software

Controls                                            

7 Soft Buttons

Buttons                                             

 

On/Off, Backlight, λ/↑, dB-dBm/↓, Zero Reference/Select, Save/Delete,         Test/Results

Power                                               

2x AA Batteries or AC Power Converter

Low Battery Indicator                             

Yes

Display                                             

Graphical LCD with Backlight

Auto-Shutdown

Yes
Protective rubber boot Yes
Testing reference guide Yes

Enclosure Size

L: 125 mm W: 70 mm H: 30mm

Weight                                              

230 Grams

Operation Temperature      

-10°C to +50°C (45% Hum, non condensing)

Storage Temperature

 -20°C to +60°C (75% Hum, non condensing)
OS420ST (Multimode APPLICATIONS) SPECIFICATIONS, KEY FEATURES AND APPLICATIONS
Applications Permise cable networks with multimode fiber
Wavelength (λ) 850 nm and 1300 nm
Output type LED
Modulated Frequencies CW (Continuous Wave)
Stability, 1 hour Less than 0.05 dB
Power Output >-17 dBM, individually adjustable with mechanical screw
Connector ST
Controls Front panelslide switches
Power 2 AA Batteries or AC Power Converter
Low battery indicator Yes
Protective rubber boot Yes
Enclosure Size

L: 125 mm, W: 70 mm, H: 30 mm

Weight 180 gram
Operation Temperature -10°C to +50°C (45% Hum, non condensing)
Storage Temperature -20°C to +60°C (75% Hum, non condensing)
OS430ST (Single mode APPLICATIONS) SPECIFICATIONS, KEY FEATURES AND APPLICATIONS
Applications Outside plant single-mode
Wavelength (λ) 1310nm/1550nm
Output type Laser
Modulated Frequencies 2 kHz/CW (Continuous Wave)
Stability, 1 hour Less than 0.05 dB
Power Output >-8 dBm, individually adjustable with mechanical screw
Connector ST
Controls Front panelslide switches
Power 2 x AA Batteries or AC Power Converter
Low battery indicator Yes
Protective rubber boot Yes
Enclosure Size L: 125 mm, W: 70 mm, H: 30 mm
Weight 180 Grams
Operation Temperature -10°C to +50°C (45% Hum, non condensing)
Storage Temperature -20°C to +60°C (75% Hum, non condensing)
MSP200XP SPECIFICATIONS, KEY FEATURES AND APPLICATIONS
Applications Multimode and Single mode
Optical Magnification 200x
LED Rated life 100,000 Hrs
Controls Momentary On/Off switch, Fine-Focus control
Safety Filter Built in IR filter

Adapter Interface

2,5 mm universal standard – optional 1,25 mm available
Power Requirements 3 pieces 1,5 Volt AAA alkaline Batteries
Size L: 225 mm, Diameter 32 mm
Weight 0.6Kg
OM200A Reporter software specifications SPECIFICATIONS, KEY FEATURES AND APPLICATIONS
Number of measurements 500 measurements
User information Company name
Phone number
Name
Job ID
Fiber parameters User fiber ID
Fiber type
Fiber details
Connector type
Meter readings Model meter
Calibration date
Reading ID
Result
NanoWatt
dB/dBm
Wavelength
Time and date
Meter fiber parameters Fiber length (km)
Number of connectors
Number of splices
Fiber analyse results Wavelength
Actual reading
Allowable loss
Overhead margin
Pass/fail
Qualified CE, RoHS and WEEE